| Instrument |
1. Digital Thermometer ( PATOS DE - 305 )
2. 100W ( 240V ) Sport Light |
| Method |
1. Put the tested specimen under the sport light ( 10 cm distances ).
2. Switch on the sport light for 30'S then switch off.
3. Put the sensor rod on the surface of the tested specimen then get the reading. |
Tested Specimen\
Time ( Second ) |
Breathable Fibre |
Leather |
PVC |
PU |
Remark |
| 0' S |
45°c |
55°c |
75°c |
80°c |
Room Temp. 26°c |
| 30' S |
33°c |
45°c |
55°c |
50°c |
| 60' S |
29°c |
39°c |
45°c |
40°c |
|
|
| |
 |
| Instrument |
1. Digital Thermometer ( PATOS DE - 305 )
2. Refrigerator |
| Method |
1. Put the tested specimen under the sport light ( 10 cm distances ).1. Put the tested
specimen into the non-frost freeze compartment.
2. Take out the tested specimen from the compartment and put the sensor rod on the
surface of the tested specimen under the room temperature then get the reading. |
Tested Specimen\
Time ( Second ) |
Breathable Fibre |
Leather |
PVC |
PU |
Remark |
| 0' S |
12°c |
10°c |
8°c |
12°c |
Room Temp. 26°c
Freeze Compartment
Temp. : 6°c |
| 30' S |
22°c |
17°c |
16°c |
22°c |
| 60' S |
24°c |
21°c |
20°c |
24°c |
|
|
 |
 |
|
| |
| |
|